Solar Generator & Power Station Sizing Calculator

Size portable power stations and solar generators. Calculate battery watt-hours (Wh), inverter continuous/surge wattage, appliance runtimes, and solar recharge hours.

☀️ Solar & Energy☀️ Solar Energy⚡ Photovoltaic System
Appliance / Device Running (W) Daily Hours Surge (W) Energy (Wh) Action

Recommended Power Station Specifications

Battery Capacity Needed
0 Wh
Minimum Nameplate Wh
Inverter Continuous Watts
0 W
Including 25% Buffer
Peak Surge Requirement
0 W
Motor Inrush Rating
Solar Recharge Time
0 hrs
Under Direct Sunlight
Quick Overview & Direct Answer

Solar Generator & Power Station Sizing Calculator - Wh, Watts & Solar Input: Free Solar Generator & Power Station Sizing Calculator tool: size portable power stations and solar generators. Calculate battery watt-hours (Wh).

Primary Use Solar panel wattage estimation, battery bank sizing, energy payback time
Input Formats Daily kWh usage, sun hours, panel wattage rating
Output Format System size in kW, recommended battery capacity, annual output
Processing Mode 100% Client-Side Solar Modeling
Access Tier Free, unlimited, no sign-up needed

How to Use the Solar Generator & Power Station Sizing Calculator - Wh, Watts & Solar Input

1

Add Essential Household or Camping Appliances

Click the appliance presets (fridge, CPAP, router, laptop) or type custom power ratings.

2

Verify Running Watts and Duty Cycles

Input realistic daily run hours (e.g., a refrigerator compressor runs ~8 hours in a 24-hour cycle).

3

Select Battery Chemistry & Autonomy Margin

Choose between long-life LiFePO4 (90% DoD) or NMC (80% DoD) and set desired days of reserve storage.

4

Evaluate Power Station & Solar Input Requirements

Review the required watt-hour (Wh) capacity, inverter wattage, and solar panel recharging timeline.

Engineering Guide: Principles & Formula Details

Sizing a portable power station or "solar generator" demands rigorous separation between electrical capacity (Watt-hours or Amp-hours) and instantaneous power output (continuous and peak surge Watts). While capacity dictates how long devices can operate before the battery depletes, inverter wattage dictates which appliances can physically be turned on without tripping overload protection circuits.

Inductive motor loads—such as compressor-driven refrigerators, portable air conditioners, power tools, and sump pumps—draw high inrush currents during motor startup that can reach three to five times their continuous running wattage. An inverter must sustain this millisecond surge. For example, a 150W refrigerator can spike to 800W for half a second upon startup. Sizing calculators must ensure the pure sine wave inverter rating accommodates simultaneous baseline loads plus the largest single motor surge.

Battery chemistry fundamentally determines usable capacity and long-term lifespan. Traditional lithium nickel manganese cobalt (NMC) batteries offer high energy density but degrade after 500 to 1,000 charge cycles and are typically discharged to 80% Depth of Discharge (DoD). Modern Lithium Iron Phosphate (LiFePO4 / LFP) chemistry provides superior thermal stability, safely supports 90% DoD, and delivers 3,500 to 6,000 cycles before declining to 80% original capacity—translating to 10+ years of daily cycling.

Solar recharging requires matching the power station built-in MPPT (Maximum Power Point Tracking) charge controller specifications. Every solar generator has strict maximum solar input wattage, open-circuit voltage (Voc), and amperage limits (e.g., 60V, 15A, 500W max). In real-world outdoor conditions, solar panels produce roughly 75% to 85% of their rated STC wattage due to sun angle, dust, and temperature heating, requiring realistic solar harvest calculations.

Key Engineering Features & Advantages

🔋

Custom Appliance Ledger

Add multiple concurrent devices with specific duty cycles and motor surge ratings.

⚡

Surge vs Continuous Analysis

Distinguishes between continuous pure sine wave watts and motor starting surge requirements.

🔬

Chemistry Depth of Discharge

Accurately calculates usable energy for LiFePO4 (90% DoD), NMC (80%), and Lead-Acid (50%).

☀

Real-World Solar Recharge

Derates solar panel input by 18% to reflect real-world thermal losses, dust, and MPPT tracking.

🛑

Autonomy Buffer

Allows sizing for 1 to 5 days of reserve emergency power during extended grid blackouts.

🔌

Market Compatibility

Provides benchmarks matching standard market offerings (Jackery, EcoFlow, Bluetti, Anker).

Frequently Asked Questions

To power a standard full-size refrigerator (which draws ~150W running, spikes to ~800W surge, and runs about 8 hours cumulative per day for ~1,200 Wh/day), you need at least a 1,500 Wh to 2,000 Wh power station with a 1,000W continuous / 2,000W surge inverter, paired with 300W to 400W of solar panels.

Watts (W) measures the rate of electricity consumption at any single instant (like vehicle speed in mph). Watt-hours (Wh) measures the total volume of energy consumed over time (like miles driven). Running a 100W laptop charger for 3 hours consumes 300 Wh of energy.

LiFePO4 (lithium iron phosphate) is chemically non-combustible, does not experience thermal runaway, allows deeper discharge without damage, and lasts 3,500 to 6,000 full cycles (10-15 years) compared to 500-800 cycles for traditional lithium NMC batteries.

Only if the panel voltage (Voc) and current (Amps) fall within your power station solar input specifications. Exceeding the maximum open-circuit voltage rating will permanently destroy the internal MPPT charge controller.